West Chester, PA, Cooling Services
Don’t get stuck in a hot and sticky house all summer when your air conditioner malfunctions. Instead, schedule emergency repairs with a trusted local HVAC company in West Chester, PA. At DiBiase Heating and Cooling Company, our AC contractors can quickly get your unit up and running. Whether you need routine AC tune-ups or urgent AC repairs, we can handle it.
Call DiBiase Heating and Cooling Company for on-time services in West Chester, PA, and the surrounding areas. All of our technicians are background-checked and drug-tested! We provide complete cooling services, including:
- Commercial HVAC services
- Air conditioning repairs and maintenance
- Air conditioning installations and replacements
- Air handler services
- AC filter replacements
- AC refrigerant leak repairs
- Ductless mini split AC services
- Smart thermostats
- Evaporator coil services
AC Emergency Repairs: What To Do When Your Air Conditioner Stops Cooling Your House
If your central air conditioning system stops working correctly, it must be repaired quickly. You need emergency AC repairs to restore comfort to your house as soon as possible – especially if it’s extremely hot outside in West Chester, PA.
While waiting for the AC contractor to arrive, you should complete the following steps:
- Make sure the thermostat is set to Cooling.
- Make sure the circuit breaker isn’t tripped and is working correctly.
- Make sure the air filter is clean. If it’s clogged, then it needs to be replaced.
A technician will perform a complete inspection when they arrive and quickly get your air conditioner up and running again.
What to Expect When AC Installers Arrive for AC Replacements
When you need a new air conditioner installed, you likely have many questions. To help, we want to put you at ease about what you can expect to happen at your house when our DiBiase Heating and Cooling Company technicians arrive.
First, they will talk to you about the job and discuss what you can expect throughout the installation. They might provide you with a packet of information about the system, instructions you need to follow, and other vital details. It may also include an invoice or estimate for the work.
You should review the information prior to the technicians starting. If you see any errors, please let the professionals know as soon as possible during the AC replacement process.
Common Ductless Mini Split AC System Repairs
Occasionally, your ductless mini split AC system might require repairs. Our experts at DiBiase Heating and Cooling Company encounter numerous issues in West Chester, PA, including these common repairs:
- Refrigerant leaks
- Leaks or clogs in the condensate drain
- Frozen coils
- A malfunctioning thermostat
- Reduced airflow due to faulty fans or blowers
- Wiring issues
- Problems with the sensor
- Odd noises coming from the unit
- A malfunctioning compressor
If you suspect your ductless system is experiencing these issues, call our experts at DiBiase Heating and Cooling Company.
West Chester, PA, Heating Services
Is your heater failing to keep your house warm and comfortable? You need a trusted professional to inspect it! Call our trusted technicians at DiBiase Heating and Cooling Company for emergency furnace repairs in West Chester, PA. We offer 24/7 services!
Our experienced heating contractors can identify if there is an issue and repair it to restore comfort to your house quickly. DiBiase Heating and Cooling Company provides complete heating services to West Chester, PA, and the surrounding areas, including:
- Thermostats
- Boiler services
- Heat pumps
- Commercial HVAC services
- Furnace repairs and maintenance
- Furnace installations and replacements
- Heater repair and maintenance
- Heater installation and replacements
- Geothermal heating & cooling services
What To Know Before Buying a New Heater
Buying a new heater is a big decision. Because it is a significant investment, you want to ensure you are getting the best unit for your house. There are certain criteria our heating contractors recommend considering before buying a system.
Some questions they often ask clients are:
- What type of fuel or energy source do you have access to?
- How big of a space do you need to be heated?
- How much do you want to spend on a new system?
- What level of climate control do you want?
When you need heating replacement, trust the work of our experts at DiBiase Heating and Cooling Company. We offer quality central heating installation services in West Chester, PA, and the surrounding areas!
Heating Emergencies: How to Prevent Dangerous Furnace Problems
Problems with your furnace can quickly put your household at risk. If a serious issue develops, the system can put your family at risk of fires and carbon monoxide leaks.
Fortunately, you can prevent these problems by taking the proper steps. Scheduling regular preventative maintenance on your unit can help technicians identify problems that can lead to potentially dangerous issues later. During heater tune ups, experts can repair the problem before your family is at risk.
If you need to schedule furnace maintenance, call our furnace contractors for appointments in West Chester, PA, and beyond! DiBiase Heating and Cooling Company provides the ultimate customer experience; your satisfaction is 100% guaranteed.
What Technicians Look for During Heat Pump Maintenance
Yearly maintenance services on your heat pump are necessary to keep your system working correctly. During these appointments, technicians from our top-ranked furnace service company will perform a complete inspection of your system, including:
- Check the air filter and replace it if needed.
- Calibrate the thermostat to ensure the temperature is accurate.
- Check the refrigerant levels.
- Inspect and clean the coils.
- Examine the condensate drain line for clogs or blockages.
- Check the electrical components for wiring issues and other damage.
- Inspect the components and parts and make sure they are working correctly.
- Check the ductwork for leaks.
- Check the refrigerant lines.
Home Energy Audits
DiBiase Heating and Cooling provides comprehensive home energy audits to help homeowners in West Chester improve energy efficiency and reduce utility bills. Our detailed audits identify areas where energy is being wasted and provide tailored solutions to maximize your home’s comfort and savings.
Our energy audit services include:
- Identifying air leaks: We check for gaps, cracks, and drafts around doors, windows, and other areas that allow conditioned air to escape.
- Inspecting insulation: We assess the quality of your insulation to ensure it’s effectively keeping your home warm in the winter and cool in the summer.
- Evaluating HVAC performance: We examine your heating and cooling systems to determine if they’re operating efficiently or in need of repair or replacement.
- Providing energy-saving recommendations: Based on our findings, we offer solutions such as air sealing, insulation upgrades, and system improvements to help you save on energy costs.
With a professional energy audit from DiBiase, you can identify ways to reduce energy waste and enjoy a more comfortable home. Contact us today to schedule your audit!
Water Heater Services
DiBiase Heating and Cooling provides expert water heater services to keep your home’s hot water flowing reliably. Whether you need a repair, replacement, or new installation, our experienced technicians are ready to help.
Our water heater services include:
- Water heater repairs: We diagnose and fix issues with both tank and tankless water heaters, restoring your hot water quickly.
- Water heater replacement: If your unit is outdated or beyond repair, we offer energy-efficient replacements to meet your home’s needs.
- Tank and tankless options: We install both traditional tank-style water heaters and modern tankless systems, providing hot water solutions that fit your household’s requirements.
Contact us today to ensure your water heater operates efficiently year-round.
Water Treatment Services
At DiBiase Heating and Cooling, we understand the importance of clean, safe water for your home. Our water treatment solutions are designed to improve water quality, ensuring your family enjoys healthier water from every tap.
Our water treatment services include:
- Whole-home filtration systems: Remove contaminants like chlorine, sediment, and other impurities to provide clean, filtered water throughout your home.
- Water softeners: Protect your plumbing and appliances from hard water damage by reducing mineral buildup with our professional water softening systems.
- Tailored water solutions: We customize our water treatment systems to meet your specific water quality needs, ensuring your home has the best solution for clean, healthy water.
Let DiBiase improve your home’s water quality with our expert water treatment services.
Recent Jobs and Reviews in West Chester, PA
Our Local Reviews by City
- Ambler, PA (1)
- Aston, PA (4)
- Atglen, PA (2)
- Avondale, PA (2)
- Berwyn, PA (1)
- Brookhaven, PA (1)
- Broomall, PA (1)
- Chadds Ford, PA (1)
- Chester Springs, PA (38)
- Chesterbrook, PA (5)
- Claymont, DE (2)
- Clifton Heights, PA (1)
- Coatesville, PA (110)
- Cochranville, PA (1)
- Collegeville, PA (4)
- Collingdale, PA (4)
- Conshohocken, PA (1)
- Devon, PA (1)
- Downingtown, PA (131)
- Eagleville, PA (3)
- East Fallowfield Township, PA (7)
- Elverson, PA (3)
- Exton, PA (41)
- Folsom, PA (1)
- Gap, PA (2)
- Garnet Valley, PA (2)
- Gladwyne, PA (1)
- Glen Mills, PA (8)
- Glenmoore, PA (21)
- Glenolden, PA (1)
- Gwynedd Valley, PA (1)
- Havertown, PA (4)
- Honey Brook, PA (23)
- Kennett Square, PA (19)
- King of Prussia, PA (3)
- Landenberg, PA (2)
- Leacock-Leola-Bareville, PA (1)
- Lincoln University, PA (1)
- Malvern, PA (23)
- Media, PA (3)
- Merion Station, PA (4)
- Morgantown, PA (1)
- Newtown Square, PA (9)
- Paoli, PA (10)
- Parkesburg, PA (15)
- Phoenixville, PA (14)
- Plymouth Meeting, PA (2)
- Pottstown, PA (12)
- Ridley Park, PA (2)
- Royersford, PA (1)
- Saint Davids, PA (1)
- Swarthmore, PA (2)
- Thorndale, PA (3)
- Valley Township, PA (4)
- Wayne, PA (8)
- West Bradford Township, PA (21)
- West Brandywine Township, PA (3)
- West Chester, PA (72)
- West Grove, PA (2)
Job Locations and Reviews
Gas furnace tuneup on a 90% Checked the air filter and replaced. Checked the wiring connections and the voltages . Inspected and tested the burners and flame sensor and igniter. Flushed and tested the drain lines and furnace trap . checked the thermostat in heating mode and checked the gas pressures and the furnace safeties. Inspected the flue pipe and for bellies. checked the motor amps on the inducer operation and blower motor . Took indoor heat temp rise and tested for combustion. everything is in good working order at this time of service.
Performed inspection on trane heat pump.ran unit in emergency heat and tested heat strips and temperature split across unit also inspected indoor coil and blower motor, proceeded to go to outdoor unit and check all mechanical systems out there, including pressures and temperatures for the refrigeration system, inverter health, and both outdoor fan motor and compressor motor as well as outdoor coil condition and level of unit and ran unit in defrost mode. No issues with unit at this time.
Arrived for boiler leaking water. Once I got down to the boiler, I did see a trail of water inside the cabinet , found water sitting under the base of the condensate pump boiler seems to be fine. Nothing is leaking from any of the pipes , may have something to do with the condensate pump. I filled the pump up with water to test and found a pinhole in the 3/8 tubing from the condensate pump. I pulled out the failed piece of 3/8 tubing and ran a new section. Once completed. I tested the pump again. No issues also made sure the 3/8 tubing was secured to sidewall away from all the piping. I turned the boiler back on everything is back up and running like normal at this time of service, no charge brand new boiler , u def a year old .
Estimate
Upon arrival for no hot water customer reset break and water heater is working again. He said that water heater throws two flashes for pressure switch stuck closed. He explained to me that you have to tap power venter and reset breaker for unit to work. I removed venting from power venter to inspect both for debris and both were clean. I took cover off to pressure switch and hose was not kinked and didn’t see any issues. I went outside to check venting outside and it has a screen and 45° elbow for termination as required. I didn’t want to dig too far into power venter without speaking to Rheem since it is 7 months old. Contacted Rheem and they are shipping the entire power venter to Jeremiah. Told Jeremiah to contact us when it came in and we will come and replace it.
Found failed 40uF capacitor at outdoor equipment 20x20x1 filter Good System is a through-the-wall 2.5 ton heat pump/air handler with 10KW electric heat kit. Heat pump is on the balcony in a closet. I replaced the capacitor provided by The Point. Tested system operations after. Temperature rise 68-98 Also checked controls and wiring. Transformer tap correctly set for 208V service. Electric heat operations Good 40A System operating well at this time.
Upon arrival for no heat on a heat pump the tstat was set to heat and fan on. Walked downstairs and noticed nothing was on. Looked at ez trap and noticed float was up. Pushed float down and fan came on. Cleaned out ez trap and added condensate tabs to evap pan and condensate pump. Changed customer supplied filter. Checked the operation of the unit. Checked delta t had 66° return air and 114° supply air. 48° temp split. Unit is in normal operation at this time.
Upon arrival for maintenance on an oil boiler I shut oil off. Replaced rf-1 filter and 1.25/80°B nozzle. Cleaned electrodes and inspected cad cell. Tested transformer and tested primary. Cleaned heat exchanger, flue, and chimney base. Started unit and bled air out of lines. Performed smoke test and it was a 0. Performed a combustion test. Checked circulators and all zones and zone board. Tested auto feeder. Did not test zone to basement room. Tstat wasn’t accessible and Randy said they don’t use that room. System is in normal operation.
Replaced electric water heater with expansion tank and water safety. Tested operation and water pressure at 55. Set 120 water temp and tested. Water heater install complete
Perform precision gas furnace tuneup on 80% train gas furnace system. Paperware 501 air filter is OK. Clean flame sensor. Checked resistance of hot surface igniter. Tested blower capacitor. Check temperature rise. Performed combustion test. Also found humidifier feed tube broken. Replaced feed tube and number 35 humidifier pad and tested operation. Quarter inch saddle valve to water heater is corroded and has a small leak. Let homeowner know this. Gas furnace is a 2003 and should be replaced soon. Gas furnace is working at time of service .
Fully assessed no heating situation. Found gas furnace locked out on an ignition trial code. Found burners not lighting the entire way across. Further inspected burners and found some rust and corrosion naturally on the ends of the burners. System is 100,000 BTU natural gas. Recommended either cleaning the burners, or doing a better upgrade to the new stainless Steel burners. Homeowner decided to go with new stainless steel burners. Clean burners for now enough to get it working. Performed precision heat tuneup on American standard gas furnace. Replaced 413 air filter. Checked all electrical connections and components. Check gas pressure. Performed combustion test. Will need to give him a call once burners are in to install. Gas furnace is at time of service.
After assessing situation found broken glue joint at union coming out of furnace drain. Replaced one side of union and used primer and glue to fix leak. Ran furnace for a while no more water leaking. Furnace is working fine again at time of service.
Upon arrival for heat maintenance on heat pump tune up I changed the filter. Checked electrical and wiring and emergency heat kit. Checked blower motor and assembly. Checked delta t. Inspected coils. Checked fan motor and assembly. Checked refrigerant pressures. Forced unit into defrost. Unit is in normal operation at this time.
Perform precision heat pump tuneup on Amana heat pump system. Replace 20 x 25 x 4“ media air filter. Checked all electrical connections and components. Checked operation of emergency heat. Check temperature rise. Tested outdoor capacitor. Check refrigerant pressures and temperature at indoor and outdoor units. Heat pump system is working fine at time of service.
*The Bosch Heat Pump Repair is covered under full Warranty.* Upon arrival found thermostat malfunctioning intermittently old school prestige with eim . Replaced with eim and T10 thermostat. tested operations. System is running to manufacture specifications.
Arrived to leaking water heater and Paul showed me where the leak was coming from. Found pinhole leak in cold side hook up at anode rod. The T pipe should be replaced to ball valve as you can see it has corrosion signaling a low leak. Also I noticed a pool of water on relief valve rusting and rust running down to thermostats and elements as well. Don’t know how much other damage this could have caused. The anode rod is rusted as well. Unhooking from anode rod could destroy that as well. I highly suggest replacing the unit.
Upon arrival for maintenance on oil furnace I shut the oil tank off. I changed the filter, strainer, and nozzle. Cleaned electrodes and tested transformer. Pulled the clean out caps and checked flue and chimney to ensure that it was all clean. I checked electrical connections and blower motor and assembly. I changed the air filter. Turned on unit and bled the air out of oil line. Unit fired up and tested operation of primary control. Checked air temperature rise 66° return and 134° supply = 64°. Target air temp rise is 60°. Max out put temp is 170° with a high limit of 200°
Installed new airhandler on new return box in auxiliary drain pan. Adapted to Supply duct. Installed new returndrop with custom transition to aprilaire 2310 filter rack. Ran new lineset from. Indoor unit it to outdoor unit. Made all high and low voltage connections to unit. Installed new Honeywell t10 thermostat with eim panel. Reinstalled reme halo and Humidifier. Ran new condensate to new condensate pump and ran new Vinyl to point of indoor discharge. Set new unit on new pad with snowlegs and leveled. Installed new disconnect box with internal surge protector and sealed to wall. Piped new unit in. Brazed pressure tested evacuated and charged system. Made all high and low voltage connections to unit. Performed all test out procedures cleaned all work areas and reviewed installation. With home owner.
Performed gas heat tune up on 2002 80k but Gibson furnace. Check electrical components, low and high voltage connections inspect air filter, clean sensor burners perform combustion test check supply return air temp temperature. performed smoke test, heat exchanger failed test. Use camera to inspect heat exchanger could noticed some pinholes on heat exchanger and also other big marks that will soon be cracks. during today’s visit found several safety issues. Flexible gas line is been used inside furnace cabinet, high limit switch is missing metal shield, and heat exchanger didn’t passed safety test. Informed customer about unit condition and read tagged furnace, unit should not be in use. Repairs or replacement is needed for furnace to be back in safe working condition, turned power off to furnace and red tag furnace. called manufacturer and was told they don’t make this heat exchanger anymore. Only option we can provide is system replacement. Offer customer a home comfort consultant a
Performed tune up on amana gas furnace performed combustion analysis and checked gas pressures and temperature split across unit, inspected burners and heat exchanger as well as inducer and blower motor. Changed filter and clean drains for unit no issues with unit at this time.
Arrived to the customers home to replace his failed control board on his furnace. I turned the power off to the furnace started removing connections off of fail board remove the fail board placed in the new OEM board connected all connections in power to system back up, tested equipment with the new furnace slid off no problems. Customer has heat on his gas furnace again.
Check up on a heat pump system. Checked the air filter, and found good . Checked the wiring connections and the voltages. Checked the thermostat in all heating modes, started with electric heat. Inspected the amps for the heating elements and checked the blower amps and the operation. Took electric heat temps at the return and supply. Performed a outdoor BTU output for the heat pump. Checked the outdoor unit, wire connections and the voltages. Inspected the components and tested the amps draws for the compressor and the fan motor. The heat pump is in good working order.
Gas furnace tuneup on a 90% Checked the air filter and replaced. Also serviced the humidifier and tested , and set at 35%. Checked the wiring connections and the voltages . Inspected and tested the burners and flame sensor and igniter. Flushed and tested the drain lines and furnace trap . checked the thermostat in heating mode and checked the gas pressures and the furnace safeties. Inspected the flue pipe and fresh air for bellies. checked the motor amps on the inducer operation and blower motor . Took indoor heat temp rise and tested for combustion. everything is in good working order at this time of service.
Fully assessed no heating situation. After talking to homeowner found that he replaced his own thermostat with a Sensi Wi-Fi thermostat. Gas furnace was not heating before replacing stat. Found loose connection on flame sensor at gas furnace. This was causing it to shut off. Also found Sensi thermostat was wired incorrectly. Moved white wire from OB terminal to w terminal. Also went into the programming in the thermostat and changed the settings to conventional gas furnace and a/c. Performed combustion test on gas furnace. Gas furnace is working fine again at time of service.
.