DiBiase Heating and Cooling Company provides a full range of services to keep your home comfortable and efficient year-round in Thorndale, PA. Whether you need HVAC repair, installation, or maintenance, we’ve got you covered. Our team also specializes in improving indoor air quality with air purifiers, humidifiers, and ductwork services. Looking for water heater solutions? We offer repairs and replacements for both tank and tankless systems. Additionally, our energy services, including air sealing, insulation, and energy audits, help homeowners save on utility costs while maximizing comfort. Whatever your home’s needs, DiBiase Heating and Cooling Company is here to deliver expert service.

Founded in 2008, DiBiase Heating and Cooling Company is a family-owned and operated company that’s committed to delivering honest, reliable service. We take pride in our expertise, offering certified technicians who provide top-quality HVAC, plumbing, and energy services. What sets us apart is our focus on process and integrity—we do the job right the first time, ensuring your home is always in good hands. Ready to experience the DiBiase difference? Call 610-873-1244 or contact us online today to schedule your service!

Recent Jobs and Reviews in Thorndale, PA

Rated 5.0 out of 5 stars based on 3 customer reviews

Job Locations and Reviews

Nathan  B.
Nathan B. Checked in
Performed heating tuneup on Concorde gas furnace, unit was ran in heating mode and combustion and gas pressures were checked. Temperature split was checked, flame sensor was cleaned and checked, hot surface igniter was checked, and blower motor and inducer motor were checked. No issues with unit at this time.
Thorndale, PA 19372
Daniel R.
Daniel R. Checked in
Gas furnace tuneup on a 90% furnace . Checked the air filter and replaced , also serviced the humidifier and tested and set at 35% . Checked the wiring connections and the voltages . Flushed the drain lines and furnace traps and inspected the condensate pump. Inspected the burners and flame sensors and cleaned . Inspected the flue pipes for leaks and bellies. checked the thermostat in heating mode and checked the gas pressures and the furnace safeties. checked the motor amps on the inducer operation and blower motors. Took indoor heat temp rise and tested for combustion on the system. The furnace is in good working order at this time of service.
Thorndale, PA 19372
Nathan  B.
Nathan B. Checked in
Performed tune up on Rudd gas furnace, ran system in heating mode and tested combustion and gas pressures, tested inducer and blower motor. Tested temperature split of unit and cleaned flame sensor and checked spark ignition components. No issues with system at this time.
Thorndale, PA 19372
Kurt  M.
Kurt M. Checked in
Fully assessed no heating situation on rooftop unit. Went up to rooftop location and found nothing running. Found rollout switch tripped at burners. Examine heat exchanger, but did not see any cracks in the heat exchanger but did find that the inducer motor is very weak. Recommend replacement of inducer motor. Our office to get quote to replace inducer motor for rooftop unit. After resetting rollout heat is back on. System is working fine at time of service.
Thorndale, PA 19372
Daniel R.
Daniel R. Checked in
Gas furnace tuneup on a 90% furnace . Checked the air filter and found good . Checked the wiring connections and the voltages . Flushed the drain lines and furnace traps and inspected the condensate pump. Inspected the burners and flame sensors and cleaned . Inspected the flue pipes for leaks and bellies. checked the thermostat in heating mode and checked the gas pressures and the furnace safeties. checked the motor amps on the inducer operation and blower motors. Took indoor heat temp rise and tested for combustion on the system. The furnace is in good working order at this time of service. Please follow up with renewal payment .
Thorndale, PA 19372
Daniel R.
Daniel R. Checked in
Arrived to a comfort issue. Customer had said he hears inducer coming on but no blower operation and the temperature in the house is dropping. Found the inducer will come on and will run and run and run but no igniter having a pressure switch issue. I checked the vacuum pull on the inducer was running at 1.2 pressure switch is rated for .35. Checked and cleared all my tubing for the pressure switch checked and cleared the pressure switch itself. The system igniter would light. Every time I retested switch may have been restricted did put a price in for a warranty replacement. Customer will wait to see how the system will operate.
Thorndale, PA 19372
Daniel R.
Daniel R. Checked in
Gas furnace tuneup on a 90% furnace . Checked the air filter . Checked the wiring connections and the voltages . Flushed the drain lines and furnace traps and inspected the condensate pump. Inspected the burners and flame sensors and cleaned . Inspected the flue pipes for leaks and bellies. checked the thermostat in heating mode and checked the gas pressures and the furnace safeties. checked the motor amps on the inducer operation and blower motors. Took indoor heat temp rise and tested for combustion on the system. The furnace is in good working order at this time of service.
Thorndale, PA 19372
Kurt  M.
Kurt M. Checked in
Perform precision oil tuneup on spirit oil furnace. Replaced 16 x 25 x 1“ air filter. Checked all electrical connections and components. Found no surge protection on oil furnace provided estimate to install equipment search protector. Vacuumed out heat exchanger and smoke pipe. Replaced rf1oil filter Replaced 50 x 70 a nozzle. Check temperature rise. Perform smoke test. Performed combustion test. Oil furnace is working fine at time of service.
Thorndale, PA 19372
Kurt  M.
Kurt M. Checked in
Drain hot water heater to remove old valve. Install new Temperature & Pressure Relief Valve for hot water heater applications. Fill system and check for leaks. Test water pressure on system and measure hot water temperature at faucet to ensure temperature and pressure are not causing damage to relief valve. 11/21/24. Drain down water heater enough to remove old pressure relief valve on tank. Removed old relief valve and installed new relief valve. Filled water heater back up and also had to dry out drain pan underneath water heater. Checked water pressure and found it to be at the highest 100psi . Went to all the fixtures and purged out air out of hot lines. Explained to homeowner that the main whole house pressure reducing valve, which, according to homeowner is approximately 15 years old malfunctioning when we don’t see it. Provided estimate to replace whole house pressure reducing. Reminder decided to replace pressure whole house, pressure reducing valve. Had someone run out the
Thorndale, PA 19372
Tim M.
Tim M. Checked in
Arrived to water leak on 50 gallon ng water heater. Kyle said he heard water alarm last night and there was minimal amount of water in pan. He moved water alarm to other side of pan to get it to silence. Said no more water has leaked out since. I felt water in prv tube. Water pressure is 57 psi. Expansion tank is good still holding air. He mentioned that since the remodel one of the bathrooms isn’t getting hot. Sounds like contractors piped something wrong. Cleaned water out of pan. Think this was a burst of water from street. If problem happens again we will change the prv. Part is warranty but labor isn’t.
Thorndale, PA 19372
Review
Excellent Service
Lisa - Thorndale, PA 19372
Review
Kurt did a great job, on time and efficient
Bob - Thorndale, PA 19372
Review
Great service
Christine - Thorndale, PA 19372
Request Service
servicedetailscustomerreturningschedule
*
Details Regarding Your Request...
Optional: Drag and drop photos and/or videos:
Max. file size: 4 MB.
Your Contact and Service Location...
*
*
To Serve You Best...
Have we served you in the past?
Yes
No
*
What Is Convenient For You?
*
What time of day is best for you?
First Available
Morning
Afternoon
*

Call For Same Day Service/Emergencies at 610-873-1244 .

By pressing Submit I agree to receive phone, email, or text messages from DiBiase Heating and Cooling Company to the provided mobile number and also agree to the DiBiase Heating and Cooling Company terms and privacy policy. Message & data rates may apply. Consent is not a condition of purchase. We will never share your personal information with third parties for marketing purposes.
Back Next