Expert HVAC Service and More in Garnet Valley, PA
DiBiase Heating and Cooling Company provides a full range of services to keep your home comfortable and efficient year-round in Garnet Valley, PA. Whether you need HVAC repair, installation, or maintenance, we’ve got you covered. Our team also specializes in improving indoor air quality with air purifiers, humidifiers, and ductwork services. Looking for water heater solutions? We offer repairs and replacements for both tank and tankless systems. Additionally, our energy services, including air sealing, insulation, and energy audits, help homeowners save on utility costs while maximizing comfort. Whatever your home’s needs, DiBiase Heating and Cooling Company is here to deliver expert service.
Founded in 2008, DiBiase Heating and Cooling Company is a family-owned and operated company that’s committed to delivering honest, reliable service. We take pride in our expertise, offering certified technicians who provide top-quality HVAC, plumbing, and energy services. What sets us apart is our focus on process and integrity—we do the job right the first time, ensuring your home is always in good hands. Ready to experience the DiBiase difference? Call 610-873-1244 or contact us online today to schedule your service!
Recent Jobs and Reviews in Garnet Valley, PA
Our Local Reviews by City
- Ambler, PA (1)
- Aston, PA (4)
- Atglen, PA (2)
- Avondale, PA (3)
- Berwyn, PA (1)
- Brookhaven, PA (2)
- Broomall, PA (2)
- Chadds Ford, PA (2)
- Chester Springs, PA (42)
- Chesterbrook, PA (5)
- Claymont, DE (2)
- Clifton Heights, PA (1)
- Coatesville, PA (117)
- Cochranville, PA (1)
- Collegeville, PA (4)
- Collingdale, PA (4)
- Conshohocken, PA (1)
- Devon, PA (1)
- Downingtown, PA (140)
- Eagleville, PA (3)
- East Fallowfield Township, PA (9)
- Elverson, PA (3)
- Exton, PA (45)
- Folsom, PA (1)
- Gap, PA (2)
- Garnet Valley, PA (2)
- Gladwyne, PA (1)
- Glen Mills, PA (8)
- Glenmoore, PA (24)
- Glenolden, PA (1)
- Gwynedd Valley, PA (1)
- Havertown, PA (4)
- Honey Brook, PA (28)
- Kennett Square, PA (21)
- King of Prussia, PA (3)
- Landenberg, PA (3)
- Leacock-Leola-Bareville, PA (1)
- Lincoln University, PA (1)
- Malvern, PA (25)
- Media, PA (5)
- Merion Station, PA (4)
- Morgantown, PA (1)
- Newtown Square, PA (9)
- Paoli, PA (10)
- Parkesburg, PA (16)
- Phoenixville, PA (14)
- Plymouth Meeting, PA (2)
- Pottstown, PA (13)
- Ridley Park, PA (2)
- Royersford, PA (1)
- Saint Davids, PA (1)
- Springfield, PA (1)
- Swarthmore, PA (2)
- Thorndale, PA (3)
- Valley Township, PA (4)
- Wayne, PA (9)
- West Bradford Township, PA (22)
- West Brandywine Township, PA (3)
- West Chester, PA (77)
- West Grove, PA (2)
Job Locations and Reviews
Wired transformer from EAC contacts to power humidifier contacts during heat pump operation. Tested afterwards. Went through humidistat operation with Cymon. Cymon had attic insulation and basement air sealing work done a year or two ago.
Completed 6 month inspection for hybrid Trane XV Heat pump (3 Tons) 60,000 BTU natural gas furnace. Replaced 16x25x1 filter Measured heat pump temperature rise Tested defrost cycle For furnace: Inspected burners and inducer assembly Cleaned flame sensor, verified flame rectification circuit Ignitor in good condition, confirmed proper ohm reading Checked manifold gas pressures Measured temperature rise and static pressure Inspected wiring, controls, electric motors Combustion and draft tests: Pass System operating well at this time.
Completed Heat tune up for 5 ton Bosch inverter/ 80,000 BTU natural gas furnace. 16x20x4 filter Measured temperature rise and static pressure (in both heat pump and gas heat modes) Indoor and outdoor coil in good condition; Inspected wiring and controls including fan speed settings, equipment has surge protection. Monitored R410A refrigerant pressures. 130/345 EZ trap is clear, condensate pump in good condition. Combustion and draft tests: Pass Opened bypass humidifier damper and verified operations of humidifier. Set humidistat to 35%. Aprilaire 10 humidifier pad in good condition System operating well at this time.
Checked filter, checked air temp rise, turned on and tested humidifier, checked refrigerant pressures, tested heat pump operation. Ran furnace and performed combustion test. Unit is in normal operation.
Estimate
Performed QA on Trane Gas Furnace/Heat Pump system. Reviewed programming on system. Setup the Heat Pump and Gas Furnace lockout set points. Also increased cooling CFM air flow to 400 CFM per ton. Tested the wet switch and ez trap safeties. Poured water through the ez trap and through the furnace drains. Completed checklist form in system. Called David before leaving to let him know about the QA since they were not home during the visit. No additional follow up needed.
Performed precision a/c tune up on 2001 weather king air handler matched with 2009 Goodman r-22 a/c. Replaced 16x20x1 air filter. Checked all electrical conections and components. Tested outdoor capacitor. Found evaporator coil in attic is leaking r-22 refrigerant. Checked temperature split. Temperature split is 18 at this time. Also checked refrigerant pressures and temperatures. Head pressure on compressor was 262 very high. System is worn out. Recommended replacement of a/c and air handler. A/c is cooling at this time but do not know longevity of system.
Had an error for high pressure. Found compressor will run but not the fan motor. I checked the fan motor harness and reconnected. System came back on and both the compressor and the fan came on . I monitored the system over 30min , still running good . Please follow up with the customer on Monday to see how the system is operating. No charge for today. New system.
Removed old outdoor and gas furnace/coil, installed new drain pan, installed new gas furnace, coil and heat pump, installed new disconnect with surge protector, installed high volt with surge protector at furnace, connected supply and return metal kept 1’ filter. Flushed and adapted lineset, installed relay panel and connected low voltage, added eztrap and connected condensate, adapted flues and gas line, added supply sensor, installed tstat.
.