Expert HVAC Service and More in Atglen, PA
DiBiase Heating and Cooling Company provides a full range of services to keep your home comfortable and efficient year-round in Atglen, PA. Whether you need HVAC repair, installation, or maintenance, we’ve got you covered. Our team also specializes in improving indoor air quality with air purifiers, humidifiers, and ductwork services. Looking for water heater solutions? We offer repairs and replacements for both tank and tankless systems. Additionally, our energy services, including air sealing, insulation, and energy audits, help homeowners save on utility costs while maximizing comfort. Whatever your home’s needs, DiBiase Heating and Cooling Company is here to deliver expert service.
Founded in 2008, DiBiase Heating and Cooling Company is a family-owned and operated company that’s committed to delivering honest, reliable service. We take pride in our expertise, offering certified technicians who provide top-quality HVAC, plumbing, and energy services. What sets us apart is our focus on process and integrity—we do the job right the first time, ensuring your home is always in good hands. Ready to experience the DiBiase difference? Call 610-873-1244 or contact us online today to schedule your service!
Recent Jobs and Reviews in Atglen, PA
Our Local Reviews by City
- Ambler, PA (1)
- Aston, PA (4)
- Atglen, PA (2)
- Avondale, PA (3)
- Berwyn, PA (1)
- Brookhaven, PA (2)
- Broomall, PA (2)
- Chadds Ford, PA (2)
- Chester Springs, PA (42)
- Chesterbrook, PA (5)
- Claymont, DE (2)
- Clifton Heights, PA (1)
- Coatesville, PA (117)
- Cochranville, PA (1)
- Collegeville, PA (4)
- Collingdale, PA (4)
- Conshohocken, PA (1)
- Devon, PA (1)
- Downingtown, PA (140)
- Eagleville, PA (3)
- East Fallowfield Township, PA (9)
- Elverson, PA (3)
- Exton, PA (45)
- Folsom, PA (1)
- Gap, PA (2)
- Garnet Valley, PA (2)
- Gladwyne, PA (1)
- Glen Mills, PA (8)
- Glenmoore, PA (24)
- Glenolden, PA (1)
- Gwynedd Valley, PA (1)
- Havertown, PA (4)
- Honey Brook, PA (28)
- Kennett Square, PA (21)
- King of Prussia, PA (3)
- Landenberg, PA (3)
- Leacock-Leola-Bareville, PA (1)
- Lincoln University, PA (1)
- Malvern, PA (25)
- Media, PA (5)
- Merion Station, PA (4)
- Morgantown, PA (1)
- Newtown Square, PA (9)
- Paoli, PA (10)
- Parkesburg, PA (16)
- Phoenixville, PA (14)
- Plymouth Meeting, PA (2)
- Pottstown, PA (13)
- Ridley Park, PA (2)
- Royersford, PA (1)
- Saint Davids, PA (1)
- Springfield, PA (1)
- Swarthmore, PA (2)
- Thorndale, PA (3)
- Valley Township, PA (4)
- Wayne, PA (9)
- West Bradford Township, PA (22)
- West Brandywine Township, PA (3)
- West Chester, PA (77)
- West Grove, PA (2)
Job Locations and Reviews
The 2 wire between the problem thermostat was knicked. There was no continuity. I pulled wire from behind trim and found the Knick. Was almost a complete break. Because there was plenty of wire to work with I pulled some up and tested continuity. No other breaks. Homeowner will mount thermostat now that the break is gone. The (2) circulators are controlled using outdated methods. May be a good idea to install 2 zone boiler relay. Tested system operations. Good At the end of my time here the display on the thermostat they had bough went blank. I left estimate for T4 heat only thermostat. Combustion and draft tests pass. Charged for wiring repair.
Customer installed nest thermostat on 2 wire system that goes to aquastat so the nest has no way to charge itself and once it dies the zone it’s connected to has no heat. Customer stated she will go get and install thermostat herself. Removed nest for customer
Formed quality assurance on recently installed train communicating heat pump system. Checked over all the electrical wiring and connections. Checked refrigerant pressures and temperatures at indoor and outdoor unit. Checked overall penetrations. Tested condensate drain with water checked over all the settings in Trane Link thermostat and made sure everything was correct. Talk to customer about any concerns or problems. System is working fine at quality assurance.
.
Removed air handler and heat pump, installed air handler and heat pump, 30x60 drain pan, flushed lineset, cut new attic hatch for unit to fit, installed condensate to gravity drain, ez trap and wet switch, installed thermostat and EIM board, adapted to supply and return, installed 15kw heat kit, installed disconnect with surge protector and ECM motor protector, connected high and low volt wires 7-18-24 Luis return visit to start up system. Set up programming on thermostat check refrigerant charge added some refrigerant to achieve correct sub cooling levels. Added union on drain line to flush with nitrogen then water ok. check air flow food splits. Test all three stages of electric heat ok showed customer how to use thermostat and left manual by controller.
Estimate
Fully assessed no cooling situation. Found 1993 heat pump. Gave system a call from the thermostat and found air handler came on but not outdoor heat pump system. Homeowner has been running off of emergency heat for the past few years. Performed megometer test on compressor, compressor has failed. System is not repairable , also found thermostat wiring torn up out side and suctionline kinked. Recommended replacement of entire heat pump system. Duct work in attic was also not done correctly. Tony to give replacement options.
Found system locked out on an 04 code ( locked rotor). Tested capacitor, capacitor was good. Recommended installing a hard start kit, installed a tk05 hard start kit with potential relay. Reset system and tested operation. A/c is working fine at time of service.
Met with owner. Described what he’s trying to accomplish talked about possible solutions. Will be emailing quote to customer.
Performed ac tuneup. Set for cooling at thermostat and began checking all electrical connections and amp draw to indoor unit, checked temp split across coil, checked for surge protection on motor, no motor protection. there is surge protection on outdoor unit. Checked and changed 413 filter. Checked refrigerant pressures outside, inspected coil and fan compartment, we checked capacitor and amp draw to outdoor unit. System is running fine at time of tune up. Cycle unit couple times ok. noticed water heater is from 2014. Provided estimate for replacement.