Expert HVAC Service and More in Thorndale, PA
DiBiase Heating and Cooling Company provides a full range of services to keep your home comfortable and efficient year-round in Thorndale, PA. Whether you need HVAC repair, installation, or maintenance, we’ve got you covered. Our team also specializes in improving indoor air quality with air purifiers, humidifiers, and ductwork services. Looking for water heater solutions? We offer repairs and replacements for both tank and tankless systems. Additionally, our energy services, including air sealing, insulation, and energy audits, help homeowners save on utility costs while maximizing comfort. Whatever your home’s needs, DiBiase Heating and Cooling Company is here to deliver expert service.
Founded in 2008, DiBiase Heating and Cooling Company is a family-owned and operated company that’s committed to delivering honest, reliable service. We take pride in our expertise, offering certified technicians who provide top-quality HVAC, plumbing, and energy services. What sets us apart is our focus on process and integrity—we do the job right the first time, ensuring your home is always in good hands. Ready to experience the DiBiase difference? Call 610-873-1244 or contact us online today to schedule your service!
Recent Jobs and Reviews in Thorndale, PA
Our Local Reviews by City
- Ambler, PA (1)
- Aston, PA (4)
- Atglen, PA (2)
- Avondale, PA (3)
- Berwyn, PA (1)
- Brookhaven, PA (2)
- Broomall, PA (3)
- Chadds Ford, PA (2)
- Chester Springs, PA (45)
- Chesterbrook, PA (5)
- Claymont, DE (2)
- Clifton Heights, PA (1)
- Coatesville, PA (126)
- Cochranville, PA (1)
- Collegeville, PA (4)
- Collingdale, PA (4)
- Conshohocken, PA (2)
- Devon, PA (1)
- Downingtown, PA (157)
- Eagleville, PA (3)
- East Fallowfield Township, PA (10)
- Elverson, PA (3)
- Exton, PA (47)
- Folsom, PA (1)
- Gap, PA (2)
- Garnet Valley, PA (3)
- Gladwyne, PA (1)
- Glen Mills, PA (8)
- Glenmoore, PA (28)
- Glenolden, PA (1)
- Gwynedd Valley, PA (1)
- Havertown, PA (4)
- Honey Brook, PA (29)
- Kennett Square, PA (23)
- King of Prussia, PA (3)
- Landenberg, PA (3)
- Leacock-Leola-Bareville, PA (1)
- Lincoln University, PA (2)
- Malvern, PA (25)
- Media, PA (8)
- Merion Station, PA (4)
- Morgantown, PA (1)
- Newtown Square, PA (9)
- Paoli, PA (11)
- Parkesburg, PA (17)
- Phoenixville, PA (14)
- Plymouth Meeting, PA (2)
- Pottstown, PA (15)
- Ridley Park, PA (3)
- Royersford, PA (2)
- Saint Davids, PA (1)
- Spring City, PA (3)
- Springfield, PA (1)
- Swarthmore, PA (2)
- Thorndale, PA (3)
- Valley Township, PA (4)
- Wayne, PA (10)
- West Bradford Township, PA (23)
- West Brandywine Township, PA (5)
- West Chester, PA (84)
- West Grove, PA (2)
Job Locations and Reviews
Luis arrived quickly and was very courteous and professional. He asked specific questions to understand my concerns with the roof vent pipe on my home and worked to resolve the issues. Thank you Luis!
Hello Sharon! Thank you for your kind words! We're glad to hear that Luis provided prompt, professional service and took the time to address your concerns. We appreciate your trust in DiBiase Heating and Cooling and are always here to help!

Customer has 80% furnace in the basement exhaust goes all the way to the roof termination up in the attic couple years ago She had a leak. Roofer came out and silicon the flue pipe at the roof termination. She thinks it might be leaking again, went up at the attic. Inspect connection did not see any leaks, went up to the roof and inspect roof jacket and storm hood. Reapply silicon around the base and also storm hood. Customer will take a look at the attic when it’s raining.

.

Arrive for no heat situation. We were out here 2 weeks ago for some repairs. Found unit on a rollout switch open. Reset the rollout and tested operation. Upon duration of test found a burning smell from exhaust pipe. Tried to perform a combustion test, analyzer kept going off for high CO. Removed unit to inspect heat exchanger and found a lot of debris from heat exchanger corroding that is preventing it from burning correctly and venting appropriately which is causing flames to rollback. Also upon inspection it was found that the burner compartment is getting too hot especially to the touch. At this point I will follow up with the manufacture with the heat exchanger being default. Due to age and condition, would recommend getting an estimate to replace system. Office to follow up with customer.

Turn power off to the Rooftop unit. Remove the failing Inducer Motor. Install a new OEM Inducer Motor. Complete all wiring connections. Put the unit into heating mode and perform combustion testing. 12/30/24. Removed existing inducer assembly and installed new inducer. Used high temperature caulk around inducer assembly. Also performed tune up on rooftop system. Installed (4) new 16x20x1 air filters. Installed new A39 belt. Performed combustion test. Inspected burners. Roof top gas furnace is working fine at this time. 2 year guarantee on inducer.

Customers having issues with the heat for about a week now where there’s no ignition right away. Boiler tries to fire, but it doesn’t stay lit check oil pressure coming in 140 psi inspect electro transformer and cad cell. Check igniter seems to be weak and also cad cell is all yellow. Inspect heat exchanger boiler. Will need to get clean soon inform this to customer. Provided estimate to replace those parts transformer and cad cell. Customer approved repairs. Realign electrodes and replace nozzle test transformer and entire boiler. Boiler came on with no problems, test water, pressure and temperature aquastat It’s cutting off at 180 coming back on at 165. Water pressure is 12 psi. Cycle boiler couple times ok. Provided estimate to do service plan and also replace electrodes.

Performed heating tuneup on Concorde gas furnace, unit was ran in heating mode and combustion and gas pressures were checked. Temperature split was checked, flame sensor was cleaned and checked, hot surface igniter was checked, and blower motor and inducer motor were checked. No issues with unit at this time.

Gas furnace tuneup on a 90% furnace . Checked the air filter and replaced , also serviced the humidifier and tested and set at 35% . Checked the wiring connections and the voltages . Flushed the drain lines and furnace traps and inspected the condensate pump. Inspected the burners and flame sensors and cleaned . Inspected the flue pipes for leaks and bellies. checked the thermostat in heating mode and checked the gas pressures and the furnace safeties. checked the motor amps on the inducer operation and blower motors. Took indoor heat temp rise and tested for combustion on the system. The furnace is in good working order at this time of service.

Performed tune up on Rudd gas furnace, ran system in heating mode and tested combustion and gas pressures, tested inducer and blower motor. Tested temperature split of unit and cleaned flame sensor and checked spark ignition components. No issues with system at this time.

Fully assessed no heating situation on rooftop unit. Went up to rooftop location and found nothing running. Found rollout switch tripped at burners. Examine heat exchanger, but did not see any cracks in the heat exchanger but did find that the inducer motor is very weak. Recommend replacement of inducer motor. Our office to get quote to replace inducer motor for rooftop unit. After resetting rollout heat is back on. System is working fine at time of service.

Gas furnace tuneup on a 90% furnace . Checked the air filter and found good . Checked the wiring connections and the voltages . Flushed the drain lines and furnace traps and inspected the condensate pump. Inspected the burners and flame sensors and cleaned . Inspected the flue pipes for leaks and bellies. checked the thermostat in heating mode and checked the gas pressures and the furnace safeties. checked the motor amps on the inducer operation and blower motors. Took indoor heat temp rise and tested for combustion on the system. The furnace is in good working order at this time of service. Please follow up with renewal payment .
Excellent Service
Kurt did a great job, on time and efficient
Great service