Expert HVAC Service and More in Swarthmore, PA
DiBiase Heating and Cooling Company provides a full range of services to keep your home comfortable and efficient year-round in Swarthmore, PA. Whether you need HVAC repair, installation, or maintenance, we’ve got you covered. Our team also specializes in improving indoor air quality with air purifiers, humidifiers, and ductwork services. Looking for water heater solutions? We offer repairs and replacements for both tank and tankless systems. Additionally, our energy services, including air sealing, insulation, and energy audits, help homeowners save on utility costs while maximizing comfort. Whatever your home’s needs, DiBiase Heating and Cooling Company is here to deliver expert service.
Founded in 2008, DiBiase Heating and Cooling Company is a family-owned and operated company that’s committed to delivering honest, reliable service. We take pride in our expertise, offering certified technicians who provide top-quality HVAC, plumbing, and energy services. What sets us apart is our focus on process and integrity—we do the job right the first time, ensuring your home is always in good hands. Ready to experience the DiBiase difference? Call 610-873-1244 or contact us online today to schedule your service!
Recent Jobs and Reviews in Swarthmore, PA
Our Local Reviews by City
- Ambler, PA (1)
- Aston, PA (4)
- Atglen, PA (2)
- Avondale, PA (3)
- Berwyn, PA (1)
- Brookhaven, PA (2)
- Broomall, PA (3)
- Chadds Ford, PA (2)
- Chester Springs, PA (45)
- Chesterbrook, PA (5)
- Claymont, DE (2)
- Clifton Heights, PA (1)
- Coatesville, PA (126)
- Cochranville, PA (1)
- Collegeville, PA (4)
- Collingdale, PA (4)
- Conshohocken, PA (2)
- Devon, PA (1)
- Downingtown, PA (157)
- Eagleville, PA (3)
- East Fallowfield Township, PA (10)
- Elverson, PA (3)
- Exton, PA (47)
- Folsom, PA (1)
- Gap, PA (2)
- Garnet Valley, PA (3)
- Gladwyne, PA (1)
- Glen Mills, PA (8)
- Glenmoore, PA (28)
- Glenolden, PA (1)
- Gwynedd Valley, PA (1)
- Havertown, PA (4)
- Honey Brook, PA (29)
- Kennett Square, PA (23)
- King of Prussia, PA (3)
- Landenberg, PA (3)
- Leacock-Leola-Bareville, PA (1)
- Lincoln University, PA (2)
- Malvern, PA (25)
- Media, PA (8)
- Merion Station, PA (4)
- Morgantown, PA (1)
- Newtown Square, PA (9)
- Paoli, PA (11)
- Parkesburg, PA (17)
- Phoenixville, PA (14)
- Plymouth Meeting, PA (2)
- Pottstown, PA (15)
- Ridley Park, PA (3)
- Royersford, PA (2)
- Saint Davids, PA (1)
- Spring City, PA (3)
- Springfield, PA (1)
- Swarthmore, PA (2)
- Thorndale, PA (3)
- Valley Township, PA (4)
- Wayne, PA (10)
- West Bradford Township, PA (23)
- West Brandywine Township, PA (5)
- West Chester, PA (84)
- West Grove, PA (2)
Job Locations and Reviews

Installed new Goodman gas furnace 90. Built transition between coil and furnace and reused return. Tapped/ caulked return and supply.. Adapted gas line and flus. Installed new nest thermostat supplied by customer and wired up all low voltage with safeties. Adapted condensate line and ran fresh air drain into the condensate line. Cleaned up work area and tested out equipment.

Estimate

Found failed inducer motor at 75,000 BTU natural gas furnace on third floor. 20 years old manufacturer date DEC 2004 Made sure there were no obstructions and that the inducer motor has truly failed. Inspected heat exchanger. Some rust, especially at eyelets. But passed smoke test. Had conversation with Alex. If he just replaces inducer motor replacement 1. There is a chance when the technician installs it the furnace will not pass a combustion analysis/test 2. Another expensive repair (control board, blower motor) may soon follow in the next few years or 3. Given the rust marks on the exchanger it will fail in a few years. For the sake of peace of mind and warranties I advised to replace the furnace. Set up consultation today for 6PM-8PM. Dillon. AC is 4 years old. An EIM with a 3 wire communicating thermostat is currently being used. Alex wants to use his NEST. There is 18/5 wire between stat and furnace. And 18/5 wire between outdoor unit and furnace. NOTE: blue and yel

Returned to site with replacement dual pressure switch. Upon arrival the system was turned off at the thermostat. Turned to heat mode and went down to the furnace. Found Blower Motor running and unit was in an EE1 Pressure Switch error code. Removed leads from both switches and found one pressure switch was intermittently closing while testing continuity. Reconnected the old pressure switch and tried to replicate issue. Installed new pressure switches and cycled system. Allowed system to run and found no issues. Measured Pressure across the first switch at -1.8” WC with the switch rated for -1.27” WC. The drain switch was pulling around -1.0” WC and it is rated for -0.1” WC. Measured amperage on the inducer motor. Tested combustion and gas pressure.

Performed QA on Goodman gas furnace install. Tested system in heating mode and performed combustion testing and adjusted gas pressure. Tested the condensation pump to make sure it was discharging. Cycled system multiple times. Reviewed programming on system. Completed checklist form in system. We reinstalled the UV Light but it was not wired into the system. The Ballast for the UV Bulb has brown markings on the side. Would recommend replacement of the UV light system. Did not wire the UV light into the system.

Arrived at no heat call for Goodman, gas furnace, turn thermostat on the unit and waited till unit Got a call for heat, unit failed to come on multiple times and was giving an error code. Error code indicated issue with the pressure switch. Pressure switch was taken off cleaned out and reattached and unit is working fine. Unit turned on and off multiple times while I was there and is now heating the home properly no other issues.
Excellent

Performed gas heat, tuneup, checked electrical connections, low and high voltage ok replaced filter, cleaned sensor and spark igniter. Replaced filter. Performed combustion test check supply and return air. furnace keeps going off on high limit, all vents are close and blower motor is set to high speed. cycle heater couple times ok.

Set new furnace in location on bricks and furnace feet. Installed provided transition between coil and furnace and panned off. Installed new 10x24 return drop with aprilaire 2410 filter box.Adapted to existing gas line and checked for leaks. Adapted to existing vent pipes. Made all high and low voltage connections to unit. Installed new 4x4 switch and outlet box. Wired condensate pump safety in series to break 24v R call to thermostat. Replaced condensate pump as old one was not working. Ran new condensate from coil to pump. Tested pump operation. Performed test out procedures. Cleaned work area and reviewed installation with home owner.

Estimate

No heat first floor system found unit off on high limit. Checked operation found blower limit not connected to its original location (hanging inside blower compartment). After deep trough check up found holes on heat exchanger. Took photos of holes and showed them to customer. At this time immediate repairs are needed and required. Will recommend getting an estimate to replace system. Current air conditioning is from 2001 and furnace from 2005. Called Goodman and found out heat exchanger was an under 20 year warranty (parts only) provided estimate to replace heat exchanger under parts only warranty. Customer still responsible for labor and other heater related parts.
I guess we'll have to see if all this insulation makes any difference before giving a final rating. In the meantime, I can rate your people and your service very highly.