Expert HVAC Service and More in Royersford, PA
DiBiase Heating and Cooling Company provides a full range of services to keep your home comfortable and efficient year-round in Royersford, PA. Whether you need HVAC repair, installation, or maintenance, we’ve got you covered. Our team also specializes in improving indoor air quality with air purifiers, humidifiers, and ductwork services. Looking for water heater solutions? We offer repairs and replacements for both tank and tankless systems. Additionally, our energy services, including air sealing, insulation, and energy audits, help homeowners save on utility costs while maximizing comfort. Whatever your home’s needs, DiBiase Heating and Cooling Company is here to deliver expert service.
Founded in 2008, DiBiase Heating and Cooling Company is a family-owned and operated company that’s committed to delivering honest, reliable service. We take pride in our expertise, offering certified technicians who provide top-quality HVAC, plumbing, and energy services. What sets us apart is our focus on process and integrity—we do the job right the first time, ensuring your home is always in good hands. Ready to experience the DiBiase difference? Call 610-873-1244 or contact us online today to schedule your service!
Recent Jobs and Reviews in Royersford, PA
Our Local Reviews by City
- Ambler, PA (1)
- Aston, PA (4)
- Atglen, PA (2)
- Avondale, PA (3)
- Berwyn, PA (1)
- Brookhaven, PA (2)
- Broomall, PA (3)
- Chadds Ford, PA (2)
- Chester Springs, PA (44)
- Chesterbrook, PA (5)
- Claymont, DE (2)
- Clifton Heights, PA (1)
- Coatesville, PA (121)
- Cochranville, PA (1)
- Collegeville, PA (4)
- Collingdale, PA (4)
- Conshohocken, PA (2)
- Devon, PA (1)
- Downingtown, PA (149)
- Eagleville, PA (3)
- East Fallowfield Township, PA (9)
- Elverson, PA (3)
- Exton, PA (47)
- Folsom, PA (1)
- Gap, PA (2)
- Garnet Valley, PA (2)
- Gladwyne, PA (1)
- Glen Mills, PA (8)
- Glenmoore, PA (27)
- Glenolden, PA (1)
- Gwynedd Valley, PA (1)
- Havertown, PA (4)
- Honey Brook, PA (28)
- Kennett Square, PA (23)
- King of Prussia, PA (3)
- Landenberg, PA (3)
- Leacock-Leola-Bareville, PA (1)
- Lincoln University, PA (1)
- Malvern, PA (25)
- Media, PA (8)
- Merion Station, PA (4)
- Morgantown, PA (1)
- Newtown Square, PA (9)
- Paoli, PA (11)
- Parkesburg, PA (17)
- Phoenixville, PA (14)
- Plymouth Meeting, PA (2)
- Pottstown, PA (14)
- Ridley Park, PA (3)
- Royersford, PA (2)
- Saint Davids, PA (1)
- Spring City, PA (1)
- Springfield, PA (1)
- Swarthmore, PA (2)
- Thorndale, PA (3)
- Valley Township, PA (4)
- Wayne, PA (10)
- West Bradford Township, PA (22)
- West Brandywine Township, PA (5)
- West Chester, PA (80)
- West Grove, PA (2)
Job Locations and Reviews
Gas furnace tuneup on a 90% furnace . Checked the air filter and replaced and serviced the customer’s humidifier and tested . Checked the wiring connections and the voltages . Flushed the drain lines and furnace traps and inspected the condensate pump. Inspected the burners and flame sensors and cleaned . Inspected the flue pipes for leaks and bellies. checked the thermostat in heating mode and checked the gas pressures and the furnace safeties. checked the motor amps on the inducer operation and blower motors. Took indoor heat temp rise and tested for combustion on the system. The furnace is in good working order at this time of service.
Customer having issues with furnace not working properly. Found furnace on pressure switch error code. Reset unit and checked operation. Check in line vacuum reading 1.45 wc pressure switches rated at 1.27 wc. Tapped on pressure switches and switches closed. Try couple times and all times had to pat in pressure switches to close. Check venting and counted 4 elbows and 2 forty fives, total equivalent lenght is 40 feet. Manufacture call for maximum of 35 feet with the number of fittings. Performed combustion test ok. Would recommend replacement of pressure switches and potentially increasing venting to 3 in.
Gas furnace tuneup on a 90% furnace . Checked the air filter and replaced . Checked the wiring connections and the voltages . Flushed the drain lines and furnace traps and inspected the condensate pump. Inspected the burners and flame sensors and cleaned . Inspected the flue pipes for leaks and bellies. checked the thermostat in heating mode and checked the gas pressures and the furnace safeties. checked the motor amps on the inducer operation and blower motors. Took indoor heat temp rise and tested for combustion on the system. The furnace is in good working order at this time of service.
Performed tune up on new Bosch gas furnace, tested combustion and gas pressures. High fire set to 10 in wc. Low fire set to 6.3. Inducer amps at .5 blower amps at 9. Return air 75 supply 130. 1.8 micro amps dc on the flame sensor and 68 ohms on the hot surface igniter. Combustion read out perfectly with no issues or problems observed on the system whatsoever.
Estimate
Arrived for a quality check up on new a/c and furnace. Started with the indoor unit . Inspected all wiring connections and fan settings. Tested the drain and trap for the condensation. Inspected the flue pipes for correct pitch. Checked the air filter and found it needs to be replaced customer ordered new filters. checked my temp splits. Outdoor unit checked for sealed penetrations and checked for outdoor unit and disconnect to be leveled . Checked my components and checked the charge. Everything is in good working order.
Discussed goals and concerns with homeowner. Assessed problem areas and took photos and thermal images. Discussed problems and potential solutions. Built proposal in-home, and reviewed together. She will discuss with her husband and reach out if she has any questions and/or would like to move forward with any recommendations.
Installed new propane indoor unit. Reused existing return box, pan and drop. Adapted to supply plenum. New condensate with wet switch and EZ trap. Added intake drain and adapted to 3” PVC for venting. Adapted to existing fuel line. Installed blower motor surge protector. Installed new outdoor unit heat pump with new 30x30 pad. Added legs underneath and a new disconnect with surge protector. Replaced 7/8 and 3/8 line set. Sealed sump pump lid and crack in floor with concrete.
Estimate
Performed precision a/c tune up on (2) heat pump systems. (1) Bosch inverter heat pump system and (1) Carrier infinity communicating system. 16x25x4 filter was ok. 1st floor carrier carriage filter to be replaced by homeowner. Checked temperature split on both systems. Found 1st floor system to be low on charge. Temperature split was only 11 degrees and coil was freezing up. Pressures were 183/70. To replace indoor coil would be approximately $4300. System is a 13 years old recommended replacement of system. System at this point will cool slightly but will freeze up pretty quickly. Set up appointment with our office to give a replacement quote.