Exton, PA, Cooling Services
Are you ready for the summer heat and humidity? You need to ensure your air conditioner is operating correctly so you can make sure your family is cool and comfortable all summer. Call our experts at DiBiase Heating and Cooling Company for complete AC services in Exton, PA.
DiBiase Heating and Cooling Company offers 24/7 services to get your system up and running quickly. We provide complete cooling services to Exton, PA, and the surrounding areas, including:
- Commercial HVAC services
- Air conditioning repairs and maintenance
- Air conditioning installations and replacements
- AC filter replacements
- AC refrigerant leak repairs
- Smart thermostats
- Air handler services
- Ductless mini split AC services
- Evaporator coil services
AC Emergency Repairs: Why Your Air Conditioner Is Leaking
When you see moisture leaking from your air conditioner, it can be alarming. You might immediately wonder what the moisture is and what’s causing it. While some moisture can be expected, others can indicate you need emergency air conditioner services.
Some potential problems that can cause AC leaks are:
- A clogged condensate line.
- A rusty condensate pan.
- A dirty or frozen evaporator coil.
- A low refrigerant level.
- Dirty air filter.
It’s essential to call our experts for emergency AC repairs as soon as you notice moisture leaking from your system. The faster our DiBiase Heating and Cooling Company professionals can repair your unit, the sooner they will restore safety.
Expected Timeline for AC Installations
When you schedule air conditioner installations in Exton, PA, it’s essential to understand the process and how long the work can take to complete.
This will prepare you for what to expect during the AC replacement and how large of disruption it will be to your household. It also lets you prepare for how long you will be left without a working AC unit, as your house can be hot and uncomfortable.
The timeline will vary by project, but AC contractors estimate the installation can take 4 to 8 hours. This includes removing the old unit and getting the new one up and running.
Benefits of Installing a Ductless Mini Split AC System
When selecting a cooling system, there are numerous benefits to installing a ductless mini split AC system in your house. Some of the top advantages can include:
- A more energy-efficient unit that will help you reduce your energy bills.
- The ability to allow for zoning in your house, controlling the temperature in individual rooms.
- An easy installation process.
- Small, flexible designs that can be mounted on walls or ceilings.
- A quiet unit that makes less noise than a traditional forced-air unit.
- A unit that doesn’t require ductwork to transport the air.
Exton, PA, Heating Services
To keep your house warm and cozy all winter, getting your heater repaired quickly is essential. Call the heating contractors at DiBiase Heating and Cooling Company for emergency heater repairs in Exton, PA. We offer 24/7 services for your convenience.
Schedule services with a trusted professional when you need heater maintenance, repairs, or installations. DiBiase Heating and Cooling Company provides complete heating services to Exton, PA, and the surrounding areas, including:
- Thermostats
- Commercial HVAC services
- Heater repair and maintenance
- Heater installation and replacements
- Geothermal heating & cooling services
- Boiler services
- Heat pumps
Schedule Emergency Heating Repairs For Carbon Monoxide Leaks in Exton
There are many risks to running your heater in the winter months. While these can adequately keep your house warm, they also pose risks to your household.
One of the biggest threats is a carbon monoxide leak. Carbon monoxide leaks can happen suddenly. If this occurs, it can be incredibly dangerous for your family – even deadly.
In a heating system, combustion occurs in the heat exchanger, and air circulates around the outside of the unit. If there is a crack in the heat exchanger, then the combustion is incomplete, and it can create a carbon monoxide buildup. If this creates a leak, it can put your family at risk.
When you need emergency heater repair services, call our company for help. DiBiase Heating and Cooling Company provides the ultimate customer experience in Exton, PA. We guarantee 100% of your satisfaction!
Symptoms That Indicate You Need a New Heater
Do you need to replace your heater ? It’s essential to watch for key symptoms. Our experts recommend watching for the following signs:
- An aging unit: If your unit is nearing the end of its lifespan, it can be time to replace it.
- Rising energy bills: If your monthly utility bills are increasing, it can indicate your unit is working too hard to warm your home.
- Bad indoor air quality: If you’ve noticed more respiratory issues while you’re in your home or seen more dust piling up around your house, it can indicate your system is not adequately removing particles from the air.
- Uneven heating in your house: If you notice hot and cold spots around your home, it can indicate your unit is not efficiently heating your house.
- Odd smells: If you start to smell exhaust or foul odors, it’s time to replace your system.
Key Components in Your Heat Pump
Numerous parts of your heat pump perform essential functions. Some key components can include:
- Outdoor unit: The outdoor unit contains a coil and a fan.
- Indoor unit: The indoor unit, or the air handler, also includes a coil and a fan.
- Refrigerant: Refrigerant absorbs and rejects heat as it circulates through the system.
- Compressor: This pressurizes the refrigerant and moves it through the unit.
- Reversing valve: This changes the refrigerant flow, allowing the unit to switch between heating and cooling.
- Expansion valve: This regulates the flow of the refrigerant as it passes through the system.
How an Energy Audit Can Help You Save
An energy audit is a powerful tool to help homeowners in Exton reduce energy waste and lower utility bills. At DiBiase Heating and Cooling Company, our expert team conducts thorough audits to identify areas where your home is losing energy, such as drafts, poor insulation, and inefficient systems.
Once we identify problem areas, we provide tailored recommendations, including air sealing, insulation upgrades, and other energy-saving solutions. By addressing these issues, you can enjoy a more comfortable home while significantly cutting down on energy costs. Let DiBiase help you save money and improve your home’s efficiency today!
Should You Repair or Replace Your Water Heater?
Deciding whether to repair or replace your water heater can be challenging.
If your water heater is less than 10 years old and experiencing minor issues like inconsistent heating or small leaks, a professional repair may be the best solution.
However, if your unit is over 10-15 years old, frequently breaking down, or no longer meeting your household’s hot water needs, replacement is often the more cost-effective option.
Upgrading to a new, energy-efficient model can improve performance, lower energy costs, and provide reliable hot water for years to come. Contact DiBiase Heating and Cooling Company to assess your system and help you make the best decision for your home.
Which Water Treatment System Is Right for Your Home?
Choosing the right water treatment system depends on your home's specific needs.
Consider a whole-home filtration system if your water has an unpleasant taste, odor, or visible impurities.
For homes dealing with hard water issues—such as mineral buildup on plumbing fixtures and appliances—a water softener is an ideal solution to protect your home’s water system and improve water quality.
DiBiase Heating and Cooling Company offers both filtration and softening solutions, tailored to ensure your home receives the best possible water treatment. Contact us today to learn which system is right for you!
Recent Jobs and Reviews in Exton, PA
Customers say: The overall sentiment of the reviews is positive, with a slight negative bias. The positive reviews highlight the efficiency, courtesy, and expertise of the technicians, as well as the quality of the service provided. Customers appreciate the professionalism, thoroughness, and willingness to explain the work done. The recurring themes include positive experiences with the company, satisfaction with the service, and the knowledge and expertise of the technicians. However, there are a few negative reviews that mention issues with pricing, sales tactics, and the need for rescheduled maintenance appointments. These negative reviews suggest that there may be some areas for improvement in the company's customer service and sales processes. In conclusion, the reviews indicate that DiBiase HVAC provides high-quality service with knowledgeable and courteous technicians. While there are a few negative reviews, the positive reviews outweigh them, and the recurring themes suggest that the company is committed to customer satisfaction. However, there may be some areas for improvement in the company's pricing, sales tactics, and rescheduled maintenance appointments.
Our Local Reviews by City
- Ambler, PA (1)
- Aston, PA (4)
- Atglen, PA (2)
- Avondale, PA (3)
- Berwyn, PA (1)
- Brookhaven, PA (2)
- Broomall, PA (3)
- Chadds Ford, PA (2)
- Chester Springs, PA (44)
- Chesterbrook, PA (5)
- Claymont, DE (2)
- Clifton Heights, PA (1)
- Coatesville, PA (121)
- Cochranville, PA (1)
- Collegeville, PA (4)
- Collingdale, PA (4)
- Conshohocken, PA (2)
- Devon, PA (1)
- Downingtown, PA (149)
- Eagleville, PA (3)
- East Fallowfield Township, PA (9)
- Elverson, PA (3)
- Exton, PA (47)
- Folsom, PA (1)
- Gap, PA (2)
- Garnet Valley, PA (2)
- Gladwyne, PA (1)
- Glen Mills, PA (8)
- Glenmoore, PA (27)
- Glenolden, PA (1)
- Gwynedd Valley, PA (1)
- Havertown, PA (4)
- Honey Brook, PA (28)
- Kennett Square, PA (23)
- King of Prussia, PA (3)
- Landenberg, PA (3)
- Leacock-Leola-Bareville, PA (1)
- Lincoln University, PA (1)
- Malvern, PA (25)
- Media, PA (8)
- Merion Station, PA (4)
- Morgantown, PA (1)
- Newtown Square, PA (9)
- Paoli, PA (11)
- Parkesburg, PA (17)
- Phoenixville, PA (14)
- Plymouth Meeting, PA (2)
- Pottstown, PA (14)
- Ridley Park, PA (3)
- Royersford, PA (2)
- Saint Davids, PA (1)
- Spring City, PA (1)
- Springfield, PA (1)
- Swarthmore, PA (2)
- Thorndale, PA (3)
- Valley Township, PA (4)
- Wayne, PA (10)
- West Bradford Township, PA (22)
- West Brandywine Township, PA (5)
- West Chester, PA (80)
- West Grove, PA (2)
Job Locations and Reviews
Upon arrival found system heating supply temp at 99. House at 55 degrees set at 65. Checked all settings and tested system. Found blower foam packaging still attached to blower. Removed and retested. Supply temps now at 133. And running to standards.
Gas furnace tuneup on 2 furnaces . Checked the air filters and replaced supplied by the customer. Checked the wiring connections and the voltages . Flushed the drain lines and furnace traps and inspected the condensate pumps on both units. Inspected the burners and flame sensors and cleaned . Inspected both flue pipes for leaks and bellies. checked the thermostats in heating mode and checked the gas pressures and the furnace safeties. checked the motor amps on the inducer operation and blower motors. Took indoor heat temp rise and tested for combustion on both units . Both furnaces are in good working order at this time of service.
Estimate
Customer called in for no heat. There’s three systems in the house. One is the sunroom which is working fine the other two main floor and second floor not working properly. After troubleshooting both units for first and second floor systems found out that both of them have crack heat exchangers. Main floor system had a blocked filter unit kept going off on high limit. On second floor unit inducer assembly is seized and not working. Provided estimate for repairs. First floor system needs heat exchanger, second floor needs new heat exchanger and inducer assembly. Burn heaters are red tagged, from now on customer is liable and they want to continue running main floor system.
Perform six month inspection on a recently install heat pump for first floor. Everything checked out good on new unit replace air filter 18 x 18 by one. Supply return our temperatures 25° outside temperatures and refrigerant level was OK. Also perform check up on the second floor heat pump check electrical low and high voltage connections and components test 5KW electric heater replace filter supply return air temperatures outside refrigerant levels, capacitor contactor recycle unit test defrost. Unit is from 2006. Customer is aware of age and condition. Running little harder than normal.
Performed two heat pump tune ups. Small heat pump front lobby checked out ok replace filter check back up heat ok. Supply and return air ok. Refrigerant levels ok on dojo unit, found unit running on auxiliary heat. Outdoor heat pump locked out on low pressure error code. Replace all 3 filters test back up heat. Reset unit and check levels. Refrigerant levels are lower than normal. This explains why they received high electric bill. Provided estimate to add refrigerant and dye to find out where unit is leaking. Would consider getting an estimate to replace system due to past history on repairs. Office to follow up with customer.
Fully assessed breaker tripping on strap heater situation. Found outdoor defrost board not wired correctly. Connected white and brown wires at outdoor unit and wired Correctly indoor air handler. Ran outdoor defrost board through test mode and found that now it is energizing strip repeater at 43 A when running in defrost mode, which is correct. After talking to tenet the breaker on the strip heater has several Nuisance trips. Whould still recommend replacement of strip Heater and breaker. Talked to landlord he would like our office to just email him over the strip heater quote only.
No heat room 109. Made a call for heat. Indoor fan motor runs but no operation from compressor check compressor capacitor reading 25 MFD check resistant across all three leads between run and start 7.4 ohms common to start zero ohms common to run zero ohms. Told Bill that the compressor it’s open on overload I cannot check compressor winding because we will need to pull the whole unit apart to get to compressor terminals. Most likely compressor over load stuck open.
No heat found no power to unit. Check 15 amp fuse and was no good. Check wiring found compressor start terminal reading high ohms between S to C and R. Install new fuse and fuse went bad as soon as the power was restored to the unit. Bill will change this unit.
No heat room memory care center 16 found unit with no thermostat. Check wiring electrical low and high voltage, jump thermostat connections to test the heat, everything came on. Check supply and return air ok getting 24° differential plate between supply and return. Bill will install thermostat.
No heat, found unit with no power, bill reset breaker and test operation found capacitor to be at fault. Reading 0 mfd rated at 25 bill had spare capacitor on site. Replace capacitor and test unit operation ok supply air 94 return air 72 cycle unit couple times ok.
Completed plan member heat tune up for 100,000 BTU modulating natural gas furnace. Homeowner replaces filter, in good condition at this time Inspected burner, heat exchanger, inducer assembly, pressure switches Cleaned flame sensor with fine steel wool, verified flame rectification circuit Ignitor in good condition, measured correct ohms Cleared EZ trap, added treatment tabs to condensate pump Inspected wiring and controls, left estimate for ECM surge protector for blower motor Measured temperature rise and static pressure Combustion and draft tests: Pass System operating well at this time. Homeowner paid for plan today.
Customer has heat pump from 2012. Tenants states that some times heat pump would pump cold air. Based on customer explanation could determine where to start. Check emergency heat 10 kw ok. Run unit in heat mode refrigerant levels and temps ok. As I was running unit the breaker for air handler tripped it stemmed like this has happened in the past. Also noticed when heat pump goes into defrost it does not send signal back to indoor air handler, wires are wire nutted on outdoor and indoor unit. Based on what I’m able to see during today’s visit. Would recommend replacement of electric heater outdoor defrost and sensor, and wired unit based in manufacture specifications. Would recommend system upgrade as main option. Customer to decide.
Me and Jacob arrived on new boiler Install not heating correctly. On arrival we did find the boiler was running . We went into house and found the temperature set at 75° house temperature was 55° for both zones . We went back to the boiler. Noticed that boiler was making a call for domestic hot water More often than the house heating. I got a hold of tech-support and tech-support showed me how to check for water flow for a call for domestic. We are getting .28 water flow, which will activate the call for domestic. We did find that a toilet was piped backwards with hot water and was leaking at the flapper, causing the domestic to run more than normal. Right now the toilet is valved off so now the house is getting a call for heat. The customer has a plumber coming back to fix the toilet issue tomorrow. Everything is back up and running at this time with the boiler, and temps are rising. no charge for today from the recall .
Arrived at call for no heat and noticed thermostat was set for recovery mode on a schedule of 5 ht cycles an hour and when I removed the schedule the unit fired in at full capacity and heated right up, told customer to set the schedule closer together, he had it at 58 and 75 so it was taking forever to heat back up, tested radiators that were all at 140 degrees and boiler was at 160, set unit for 70 degrees and to hold so it would bypass thermostat.
Perform six month inspection on recently installed heat pump no questions from customer. Replace air filter. Check supply return air temperatures test 15 kw back up electric heat check outdoor unit electrical and refrigerant pressures. Check any active error codes on thermostat no codes were showing. Cycle heat pump OK
Pump down remaining refrigerant in the system. Disconnect and remove the Coil from the Air Handler. Install new Coil in the Air Handler and braze connections. Pressure test and evacuate system. Weigh in the Factory Charge and put system into operation. Measure refrigerant charge and test system. *Coil Replacement is covered under Manufacturer's Parts Warranty.*
Heat tune up for 2 Ton communicating Heat pump with 10KW electric heat kit Replaced Aprilaire 313 filter provided by homeowner Indoor and outdoor coils in good condition Inspected wiring, controls, electric motors and components; control settings 10KW electric heat amps 38.8 Good Measured temperature rise and static pressure Verified integrity of compressor motor Checked defrost cycle/operation Verified refrigerant charge and pressures System is operating well at this time.
Fully assessed no heating situation. Found furnace had tripped rollout switch. Blower motor was not coming on. Found low voltage DC mole plug that inputs power to blower speeds seem to be loose. Pushed on connector and blower motor came on and heat is working correctly. System was recently installed. Todd wanted to increase his blower on speed tapping from tap one to tap two. Measured DC voltages at board. Tap one voltage to ground was 7.2 V DC. Tap five terminal which is energized during heating was 14 V DC. Explain to Todd that this might not be a good idea because it could damage the blower motor . He may call train himself to find out if this is possible. No charge as per recent install.
Upon arrival for maintenance on gas furnace I changed air filter. I cleaned the flame sensor. I inspected heat exchanger and burners. I checked blower motor and assembly. I checked the resistance of igniter. Checked all wiring and control board. I checked inducer operation and ensured hose port was clear. I checked gas pressures. Checked air temperature rise. Performed combustion test. Unit is in normal operation at this time.
Performed six month inspection on Trane Link hybridpropane, gas, furnace, and inverter heat pump system. Checked all electrical connections and components. Found system locked out on a code 140 which is a hardware error code. Found breakers not labeled in the panel. Had to locate both indoor and outdoor unit breakers and mark them showed homeowner how to reset in this case. Tested out both heat pump and propane gas furnace. Ramped up inverter to 100% and outdoor unit did not make any strange noises. System is working fine at time of service. Provided information on maintenance plan.
Upon arrival for maintenance on gas furnace I changed air filter. I cleaned the flame sensor. I inspected heat exchanger and burners. I checked blower motor and assembly. I checked the resistance of igniter. Checked all wiring and control board. I checked inducer operation and ensured hose port was clear. I checked gas pressures. Checked air temperature rise. Performed combustion test. Tested humidifier and water was too low. Increased water pressure slightly and tested. Unit is in normal operation at this time.
Arrived for outdoor heat pump low charge. I put my gauges on the unit found unit was low charge. I quoted the customer to perform a leak search on the system. She approved and signed off on the leak search. When performing the leak search, I found a leak on the indoor coil. Will need to see if the customer has any labor warranties coil should be covered under warranty office the follow up on Monday collected for the leak search and my diagnostics.
Performed QA on Bosch Heat Pump/Air Handler. Ran system in heating mode and tested the Auxiliary Heat Kit. Measured 20.3 Amps and 19.7 Amps across each heating element of the 10Kw Heat Kit. Reviewed programming on thermostat and fan speed settings for Air Handler. Tested the ez trap safety and filled condensation pump to test. Completed checklist form in system. No additional follow up needed.
Customer heard a noise coming from outdoor unit took a video of compressor shaking. Upon arrival found heat pop off set thermostat to run heat pump and checked operation. Everything checked out good check refrigerant levels and pressures. Call tech-support to Validate and compare EEV numbers, temperature sensors readings. Text support seeing everything within manufacture recommendations. Explain this to customer we will monitor system and if it happens again, instructed customer to just let the unit run and not turn it off.