Expert HVAC Service and More in East Fallowfield Township, PA
DiBiase Heating and Cooling Company provides a full range of services to keep your home comfortable and efficient year-round in East Fallowfield Township, PA. Whether you need HVAC repair, installation, or maintenance, we’ve got you covered. Our team also specializes in improving indoor air quality with air purifiers, humidifiers, and ductwork services. Looking for water heater solutions? We offer repairs and replacements for both tank and tankless systems. Additionally, our energy services, including air sealing, insulation, and energy audits, help homeowners save on utility costs while maximizing comfort. Whatever your home’s needs, DiBiase Heating and Cooling Company is here to deliver expert service.
Founded in 2008, DiBiase Heating and Cooling Company is a family-owned and operated company that’s committed to delivering honest, reliable service. We take pride in our expertise, offering certified technicians who provide top-quality HVAC, plumbing, and energy services. What sets us apart is our focus on process and integrity—we do the job right the first time, ensuring your home is always in good hands. Ready to experience the DiBiase difference? Call 610-873-1244 or contact us online today to schedule your service!
Recent Jobs and Reviews in East Fallowfield Township, PA
Our Local Reviews by City
- Ambler, PA (1)
- Aston, PA (4)
- Atglen, PA (2)
- Avondale, PA (2)
- Berwyn, PA (1)
- Brookhaven, PA (1)
- Broomall, PA (2)
- Chadds Ford, PA (1)
- Chester Springs, PA (38)
- Chesterbrook, PA (5)
- Claymont, DE (2)
- Clifton Heights, PA (1)
- Coatesville, PA (110)
- Cochranville, PA (1)
- Collegeville, PA (4)
- Collingdale, PA (4)
- Conshohocken, PA (1)
- Devon, PA (1)
- Downingtown, PA (131)
- Eagleville, PA (3)
- East Fallowfield Township, PA (7)
- Elverson, PA (3)
- Exton, PA (41)
- Folsom, PA (1)
- Gap, PA (2)
- Garnet Valley, PA (2)
- Gladwyne, PA (1)
- Glen Mills, PA (8)
- Glenmoore, PA (21)
- Glenolden, PA (1)
- Gwynedd Valley, PA (1)
- Havertown, PA (4)
- Honey Brook, PA (23)
- Kennett Square, PA (19)
- King of Prussia, PA (3)
- Landenberg, PA (2)
- Leacock-Leola-Bareville, PA (1)
- Lincoln University, PA (1)
- Malvern, PA (23)
- Media, PA (3)
- Merion Station, PA (4)
- Morgantown, PA (1)
- Newtown Square, PA (9)
- Paoli, PA (10)
- Parkesburg, PA (15)
- Phoenixville, PA (14)
- Plymouth Meeting, PA (2)
- Pottstown, PA (12)
- Ridley Park, PA (2)
- Royersford, PA (1)
- Saint Davids, PA (1)
- Swarthmore, PA (2)
- Thorndale, PA (3)
- Valley Township, PA (4)
- Wayne, PA (8)
- West Bradford Township, PA (21)
- West Brandywine Township, PA (3)
- West Chester, PA (72)
- West Grove, PA (2)
Job Locations and Reviews
Did a QA on a new trane 2stage gas furnace . Check the cleanliness of all the wires and connections. Inspected the the gas line to check for leaks started the gas furnace and adjusted gas pressure for the first and second stages. Checked the flue piping and checked the drain lines. Checked the control board for proper set up and checked the thermostat for set up. Checked outdoor level and the disconnect level and made sure all penetrations are caulked . Talked with the customer to see if he had any questions. The new system looks good. It’s up and running at this time of service.
Check up on a heat pump system. Checked the air filter . Checked the wiring connections and the voltages. Checked the thermostat in all heating modes. Performed an outdoor BTU output for the heat pump. Checked the outdoor unit, wire connections and the voltages. Inspected the components and tested the amps draws for the compressor and the fan motor. The heat pump is in good working order. Gas furnace tuneup on a 90% Checked the air filter. Checked the wiring connections and the voltages . Inspected and tested the burners and flame sensor and igniter. Flushed and tested the drain lines and furnace trap . checked the thermostat in heating mode and checked the gas pressures and the furnace safeties. Inspected the flue pipe and fresh air for bellies. checked the motor amps on the inducer operation and blower motor . Took indoor heat temp rise and tested for combustion. everything is in good working order at this time of service.
Had to re light customers pilot on water heater
Removed old gas furnace and A/C outdoor, installed new gas furance and A/C outdoor, installed new 3/4 and 3/8 lineset, installed conversion kit and low pressure safety switch, we adapted to existing fuel line, adapted to existing venting, reused return and added new supply, installed condensate pump with an ez trap and 3/8 vinyl tubing, added surge protector. Removed old outdoor pad and added new 36x36x3 concrete pad, installed a disconnect with surge protector and voltage monitor. Connected high and low volt wiring, cleaned work area, tested out.
Estimate
Completed heat tune up for 100,000 BTU natural gas furnace. Homeowner will replace filter next month. Inspected heat exchanger, burners, inducer assembly, and pressure switch Cleaned flame sensor, verified flame rectification circuit Inspected ignitor, confirmed ohm value Verified manifold gas pressure Measured temperature rise and static pressure There is no clean out or drain safety. Discussed and left estimate for ez trap. Inspected wiring, controls, electric motors and components. Left estimate for surge protector Combustion and draft tests: Pass System operating well at this time.
Created estimate for Amana gas furnace options and emailed to the customer.
Upon arrival, found electrical power off at the unit check system operation notice system is from 1994 burner assembly its in bad shape. look like something melted. Perform couple safety test and furnace failed all four tests, perform combustion test noticed that carbon monoxide was not stable jumping back-and-forth between 70 and 150 ppm gas pressure set to 3.5 inches water column. After performing all safety test determined that the heat exchanger is compromise. New heat exchanger is needed or system replacement. termination for exhaust and intake are not visible most likely they goe through chimney base, and it terminates on the roof. Final recommendation is system replacement and also run new intake and exhaust through the side of the house.
Gas furnace tuneup on a 90% Checked the air filter and replaced. Checked the wiring connections and the voltages . Inspected the burners and flame sensor and igniter. Flushed and tested the drain lines and furnace trap . checked the thermostat in heating mode and checked the gas pressures and the furnace safeties. Inspected the flue pipe and fresh air for bellies. checked the motor amps on the inducer operation and blower motor . Took indoor heat temp rise and tested for combustion. everything is in good working order at this time of service.
.